Product Details:
Minimum Order Quantity | 1 Number |
Differential Type | 5 Part |
Automation | Automatic |
Number Of Chambers | 2 |
Instrument Type | Fully Automatic 5 Part Hematology Analyzer |
Model Name/Number | H-560 |
FEATURES
· Low aspiration volume 15 μL
· 33 parameters
· Guaranteed dilution accuracy via automatic diluent dispensing
· Advanced platelet analysis (P-LCR, P-LCC, PDW-SD, PDW-CV)
Additional Information:
Product Details:
Instrument Name | Haematology Analyzer |
Automation | Fully Automatic |
Usage/Application | Clinical |
Brand | VSI |
User Input | Touch |
Model Name/Number | Fully Automatic Hematology Analyzer VSI-38 |
Display | Digital |
Sample Volume | Venous Mode: 10iL Venous Blood, Capillary Mode: 10iL Capillary Blood, Prediluted Mode: 20iL Capillar |
Storage | 100,000 Sample Results with Histograms |
No. Of Reagents Used | Lyse (500ml) and Diluent (20L) |
Calibration | Manual and Auto-Calibration |
Measuring Principle | Principle Impedance for Cell Counting Cyanide-free method for HGB |
Power | AC 100-240 V, 50/60 +/- 1 Hz |
Temperature | 18 ~ 35 Deg.C |
Printout | Thermal Printer, Support External Printer |
Quality Control | 3 Level QC, LJ Graph |
Languages | English, Spanish, Italian, Portuguese, etc. |
Histograms | WBC, RBC, PLT Histogram |
Size | 410 x 435 x 472 mm. Approx. |
Resolution | 800 600 |
Fully Automatic Hematology Analyzer (Double Chamber), Model (VSI-38), for complete blood count using principle of electrical resistance for count & SFT Method for HGB. Accurate & reliable results using digital filtering, blood cell overlap calibration dual way high pressure cleaning, to avoid aperture blocking. Electro hydraulic separation structure design alarm function, auto wiping/cleaning of sample needle. Large storage up to 30,000 result with histogram. Easy operation using touch screen with 640x480 LCD Display. Automatic sample sipping, mixing, testing & cleaning, in-built thermal printer and external printer Optional.
SALIENT FEATURES:
· Throughput: 35T/H 8-inch Touch Screen 20 Parameters + 3 Histograms
· Sample Volume: 10 µl
· Reagents Only
· Counting Modes
· 100,000 Sample Results
· Support LIS and External Printer
· CE Marked
TECHNICAL SPECIFICATIONS:
Principle Impedance for Cell Counting Cyanide-free method for HGB
Parameters : WBC, Neu#, Lym#, Mid#, Neu%, Lym%, Mid%, RBC, HGB, HCT, MCV, MCH, MCHC, RDW-CV, PLT, MPV, PDW, PCT, P-LCR
Histograms : WBC, RBC, PLT Histogram
Languages : English, Spanish, Italian, Portuguese, etc.
Calibration : Manual and Auto-Calibration
Quality Control : 3 Level QC, LJ Graph
Sample Volume : Venous Mode: 10iL Venous Blood
Capillary Mode: 10iL Capillary Blood
Prediluted Mode: 20iL Capillary Blood
Display : 8-inch color touch screen LCD (Liquid Crystal Display)
Resolution : 800 600
Storage : 100,000 Sample Results with Histograms
Reagent :Lyse (500ml) and Diluent (20L)
Printout : Thermal Printer, Support External Printer
Temperature : 18 ~ 35oC
Power : AC 100-240 V, 50/60 +/- 1 Hz
Size : 410 x 435 x 472 mm. Approx.
MEASUREMENT RANGE:
Parameters - Measurement Range
WBC : (0-99.9 X 109)/L
RBC : (0-9.99 X 1012)/L
HGB : (0-300.0) g/L
PLT : (0-999 X 109)/L
PERFORMANCE:
PARAMETER - PRECISION (CV)
WBC = 2.0% (7.0 – 15.0 X109)/L
RBC = 1.9% (3.5 – 6.0 X 1012)/L
HGB = 1.9% (110.0 – 180.0g)/L
MCV = 0.4% (80.0 – 110.0)/fL
LT = 4.0% (100.0 – 500.0 X 109)/L
Additional Information:
Product Details:
Minimum Order Quantity | 1 Number |
Differential Type | 3 Part |
Automation | Automatic |
Instrument Type | Hematology Analyzer |
Model Name/Number | H 360 |
Method | Electrical Impedance |
Features | -10.4'' Touchscreen l -50,000 Reports l -3 Histograms (RBC, WBC, PLT) l -1-click analysis| |
Storage | 50,000 Results with Graphs |
No. Of Reagents Used | Erba Dil / ERBA Lyse Cyanide Free / ELite H Clean |
Measuring Method | Manual, Predilute, Capillary |
Measuring Principle | RBC/PLT/WBC/ DIFF: /Electrical Impedance /Hb:Cyanide Free Colorimetry /MCV: Measured /HCT:Calculated |
Sample Mode | Whole Blood, Capillary, Pre Diluted |
TECHNICAL SPECIFICATIONS
ANALYTICAL MODES
Manual, Predilute, Capillary
TOTAL PARAMETERS
22 : WBC, RBC, HGB, HCT, MCV MCH, MCHC, RDW-CV, RDW-SD, PLT, MPV, PCT, PDW-CV, PDW-SD, P-LCR, P-LCC,
Lymph%/#, Mid %/#, Gran%/#
PRINCIPLE OF MEASUREMENT
RBC/PLT/WBC/ DIFF:
Electrical Impedance
Hb: Cyanide Free Colorimetry
MCV: Measured
HCT: Calculated
HISTOGRAMS
3 (WBC/RBC/PLT)
SAMPLE VOLUME
Whole Blood: 3 µL
Pre-diluted: 20 µL
Capillary: 20 µL
LINEARITY RANGE
WBC (x 10^3/L): 0 - 300
RBC(x 10^6/L: 0.00 - 8.50
Hb (g/dL) : 0 - 25.0
НСТ (%): 0 - 67
PLT (x 10^3/L) : 0 - 3000
CALIBRATOR
ELite H Cal (3mL)
Open Vial Stability at 2-8°C: 7 Days
TRI-LEVEL CONTROLS
Erba H5 CON L, N, H (3mL)
Open Vial Stability at 2-8°C: 14 Days
THROUGHPUT
60 Теsts/Hr
OC (L-J, X-BAR)
Yes
DATA STORAGE
50,000 Results with Graphs
DIMENSION (MM)
364x477x417
WEIGHT (KG) 25
REAGENTS
Erba Dil
ERBA Lyse Cyanide Free
ELite H Clean
INTERFACES
4 USB + 1 LAN Port
OPERATING ENVIRONMENT
15-30°C
Atmospheric pressure
70kPa-106kPa
POWER REQUIREMENT
A.C.100-240V:-50/60Hz: </=200VA
Additional Information:
Product Details:
Minimum Order Quantity | 1 Number |
Automation | Fully Automatic |
Instrument Name | Haematology Analyzer |
Brand | VSI |
Differential Type | 3-Part |
Usage/Application | Laboratory |
Number Of Chambers | 2 |
Parameters | WBC, Neu#, Lym#, Mid#, Neu%, Lym%, Mid%, RBC, HGB, HCT, MCV, MCH, MCHC, RDW-CV, PLT, MPV, PDW, PCT |
Number Of Parameters | RBC, HGB, HCT, MCV, MCH, MCHC, RDW-CV, PLT, MPV, PDW, PCT, P-LCR |
User Input | Touch |
Sample Mode | Pre-Diluted, Capillary |
Sample Volume | Venous Mode: 10iL Venous Blood//Capillary Mode: 10iL Capillary Blood Prediluted Mode: 20iL Capillary |
Storage | 100,000 Sample Results with Histograms |
No. Of Reagents Used | Lyse (500ml) and Diluent (20L) |
Calibration | Manual and Auto-Calibration |
Chamber Type | Double Chamber |
Fully Automatic Hematology Analyzer (Double Chamber), Model (VSI-38), for complete blood count using principle of electrical resistance for count & SFT Method for HGB. Accurate & reliable results using digital filtering, blood cell overlap calibration dual way high pressure cleaning, to avoid aperture blocking. Electro hydraulic separation structure design alarm function, auto wiping/cleaning of sample needle. Large storage up to 30,000 result with histogram. Easy operation using touch screen with 640x480 LCD Display. Automatic sample sipping, mixing, testing & cleaning, in-built thermal printer and external printer Optional.
TECHNICAL SPECIFICATIONS:
PRINCIPLE IMPEDANCE FOR CELL COUNTING CYANIDE-FREE METHOD FOR HGB | |
Parameters | WBC, Neu#, Lym#, Mid#, Neu%, Lym%, Mid%, RBC, HGB, HCT, MCV, MCH, MCHC, RDW-CV, PLT, MPV, PDW, PCT, P-LCR |
Histograms | WBC, RBC, PLT Histogram |
Languages | English, Spanish, Italian, Portuguese, etc. |
Calibration | Manual and Auto-Calibration |
Quality Control | 3 Level QC, LJ Graph |
Sample Volume | Venous Mode: 10iL Venous Blood Capillary Mode: 10iL Capillary Blood Prediluted Mode: 20iL Capillary Blood |
Display | 8-inch color touch screen LCD (Liquid Crystal Display) |
Resolution | 800 600 |
Storage | 100,000 Sample Results with Histograms |
Reagent | Lyse (500ml) and Diluent (20L) |
Printout | Thermal Printer, Support External Printer |
Temperature | 18 ~ 35oC |
Power | AC 100-240 V, 50/60 +/- 1 Hz |
Size | 410 x 435 x 472 mm. Approx. |
MEASUREMENT RANGE: | |
Parameters | Measurement Range |
WBC | (0-99.9 X 109)/L |
RBC | (0-9.99 X 1012)/L |
HGB | (0-300.0) g/L |
PLT | (0-999 X 109)/L |
|
Additional Information: