Product Details:
Minimum Order Quantity | 1 Number |
Product Type | Flame Photometer |
Display | 128 x 64 Graphical LCD |
Usage/Application | For determination of Sodium (Na), Potassium (K) |
Brand | VSI |
Model Name/Number | Microprocessor Flame Photometer VSI-603 |
Calcium | Available in Model VSI-604 |
Potassium | YES |
Sodium | YES |
I Deal In | New Only |
Sensitivity | General Mode: Na : 0.5 ppm, K : 0.5ppm, Li: 0.5 ppm, Ca: 15 ppm |
Resolution | 0.1 ppm/meq |
Reproducibility | < 1% coefficient of variation for 20 consecutive samples using 10 ppm Na set as Maximum Standard |
Power | 230 V +10% AC, 50 Hz |
Ignition System | Auto ignition |
Gas Control | Adjustable with knobs |
Fuel Type | LPG and dry oil free air |
Flame System | LPG & Dry Oil free Air |
Determination | Sodium and Potassium (In Model VSI-603) |
Detection | Auto detection of Flame Failure |
Curve Accuracy | +/- 2% of FS |
Calibration | Up to 5-Point calibration with curve fitting software. Multiple Calibration Curves can be stored in |
Atomizer | Axial Flow Type |
Filters | Two Filters Na & K in Model VSI-603 |
Size/Dimension | Main Unit: 365 x 245 x 220mm (L x B x H) approx.// Compressor Unit: 290 x 255 x 210 mm (LxBxH) |
Country of Origin | Made in India |
Microprocessor Flame Photometer (VSI-603) is used for the determination of sodium, potassium, calcium and lithium. It uses the latest microcontroller technology and advanced engineering techniques so as to give enhanced and reproducibility. It has soft touch membrane keys for ease of operations. This Flame Photometers come with two filters Sodium (Na) & Potassium (K). · Microprocessor Based with Printer Interface · Two Measurements in Single Aspiration · Setup Storage Facility · Sample Data Storage Facility · Curve Calibration Programmability Using Maximum of 5 Standards · Multiple Calibration Curve Saving Facility · Data Processing Through Curve Fitting Techniques, Least Square, Quadratic · Online Help Key · Direct Results in ppm and meq · Useful for Medical & Soil Testing |
Additional Information:
Product Details:
Minimum Order Quantity | 1 Number |
Product Type | Flame Photometer |
Display | 128 x 64 Graphical LCD |
Usage/Application | For determination of Sodium (Na), Potassium (K), Calcium (Ca) & Lithium (Li) |
Model Name/Number | VSI-604 |
Calcium | YES in Model VSI-604 |
Model | VSI-604 |
Potassium | YES |
Sodium | YES |
Brand | VSI |
I Deal In | New Only |
Sensitivity | General Mode: Na : 0.5 ppm, K : 0.5ppm, Li: 0.5 ppm, Ca: 15 ppm |
Resolution | 0.1 ppm/meq |
Reproducibility | < 1% coefficient of variation for 20 consecutive samples using 10 ppm Na set as Maximum Standard |
Lithium | YES In Model VSI-604 |
Ignition System | Auto ignition |
Gas Control | Adjustable with knobs |
Fuel Type | LPG and dry oil free air |
Determination | Sodium, Potassium, Calcium and Lithium |
Detection | Auto detection of Flame Failure |
Curve Accuracy | +/- 2% of FS |
Calibration | Up to 5-Point calibration with curve fitting software. Multiple Calibration Curves can be stored in |
Atomizer | Axial Flow Type |
Filters | Four Filters Na, K, Ca & Li in Model VSI-604 |
Country of Origin | Made in India |
Microprocessor Flame photometer (VSI-604) is an ideal instrument for determination of concentrations of Sodium, potassium, calcium & Lithium in the samples. It uses the latest microcontroller technology and advanced engineering techniques so as to give enhanced accuracy and reproducibility. It comes with Flame Failure Detection and Auto Gas Cutoff facility. In case of power failure, the gas cuts off automatically. In case the flame goes off accidently during work, the flame failure alarm sounds after a few seconds. The solutions are passed through the atomizer where air, sample and fuel are mixed together in the mixing chamber. The mixture is then sprayed as a very fine mist in flame. The color of the flame is changed depending upon the concentration of elements present.
The Model VSI-603 comes with two filters – Sodium (Na) & Potassium (K) and Model VSI-604 with four filters – Sodium (Na), Potassium (K), Calcium (Ca) & Lithium (Li). The instrument has 128 x 64 Graphical LCD displays, which guides the user throughout. It has a 20 keys keyboard with full numeric keypad that provides a convenient interface for entering the standard values.
SALIENT FEATURES:
· Microprocessor Based with Printer Interface (optional wherever printer interface is provided)
· User Friendly and Menu Driven Software.
· Direct Results in ppm and meq
· Auto Ignition Facility.
· Auto Gas Cut-off Facility
· Auto Flame Failure Detection
· Setup Data Storage Facility
· Sample Data Storage Facility
· Four Measurements in Single Aspiration
· Curve Calibration Programmability Using Maximum of 5 Standards
· Multiple Calibration Curve Saving Facility
· Data Processing Through Curve Fitting Techniques, Least Square, Quadratic
· Re-standardization with One Standard
· 128 x 64 Graphical LCD
· Online Help Key
· Batch-Wise, Date-Wise and Individual Result Data Printing
· RS232 Interface to download data to PC
· Useful for Medical & Soil Testing
Additional Information: