We are one of the leading manufacturer, supplier and exporter of Water/ Soil Analysis Kits (Digital/ Microprocessor Based). These Digital & Microprocessor Based Water & Soil Analysis Kits are available in six different models VSI-301, VSI-06, VSI-06D, VSI-6D1, VSI-06T & VSI-07. These Water & Soil Analyzers are manufactured under best industrial conditions.
Product Details:
Minimum Order Quantity | 1 Number |
Usage/Application | Laboratory Use |
Brand | VSI |
Application | Laboratory Use, Industrial Use |
Model Name/Number | Microprocessor Water/Soil Analysis Kit VSI-301 |
Number Of Tests | UNLIMITED |
Model Number | VSI-301 |
Product Type | Multi-parameter Water Analysis Kit |
Resolution | 0.01pH |
Power Supply | 230V +/- 10%, 50Hz AC & 12V Rechargeable Battery |
pH Range | 0-14 pH |
Number of Parameters | Seven parameters- pH, Conductivity, TDS, Salinity, Dissolved Oxygen, ORP and Temperature |
Accuracy | +/- 0.01 pH ( Relative) |
Country of Origin | Made in India |
Microprocessor Water Analyzer Kit VSI-301:
We are manufacturer, supplier & exporter of Microprocessor based Water/Soil Analysis Kits. Our Microprocessor Water/Soil Analysis Kit (VSI-301) is suitable for measurement of seven parameters i.e. pH, ORP, Conductivity, TDS, Salinity, D.O. & Temperature. The Mains/Battery operated kit is housed in a rugged fibre glass briefcase with provision to keep all the accessories inside. A 12V rechargeable battery is provded within the kit that makes it extremely useful for field and laboratory use.
Features of Digital Water/Soil/Solution Analysis Kit
Highly Accurate and Stable
Storage Memory for 1000 Samples
Computer and Printer Attachment Facility
User Friendly and Menu Driven Software
Technical Specifications of Microprocessor based Water/Soil Analysis Kit (VSI-301):
pH Measurement Range : 0-14 pH Resolution : 0.01pH Accuracy : +- 0.01 pH (Relative) Temp. Comp. : Automatic with PT-100 Probe & Manual by Keys Buffer Recognition: 4.00, 7.00, 9.20 (Automatic) Calibration: Automatic & Manual 2 Point,3 Point (Programmable) | Dissolved Oxygen Measurement Range : 0 to 20 ppm Resolution : 0.1 ppm Calibration : Automatic Accuracy : +- 0.2 ppm +- 1digit Temp. Comp. : Automatic with PT-100 Probe & Manual by Keys Pressure Comp. : 0-999 mm of Hg (Manual) Salinity Correction : 0-20 mg/l |
mV/ORP Measurement Range: - 1999 to +1999 mV Resolution: 1 mV Calibration: Manual Accuracy: +- 0.1% +- 1 digit | Temperature Measurement Range : -20 to +200oC Resolution: 0.1oC Accuracy: +- 0.2% +- 1 digit Input: PT-100 Probe Calibration: Manual |
Conductivity Measurement Range : 0-1000 mS/cm Range Selection: Automatic Resolution:0.01 uS/cm No. of Ranges : Six Accuracy:+- 0.5% Temp. Comp. : Automatic with PT-100 Probe Ref. Temp.:25oC / 20oC (Programmable) Temp. Co-efficient : 0-4% Adjustable Cell Constant : 0.05 to 2.0 Adjustable | TDS Measurement Range : 0-200 ppt Range Selection : Automatic No. of Ranges : Five Resolution : 0.1 ppm Accuracy : +- 0.5% TDS Factor : 0.5 By Default (Adjustable)
|
Salinity Measurement Range: 0-50 ppt Resolution: 0.1 ppt Temp. Compensation : Automatic Accuracy : +- 0.5% Salinity Factor : 0.75 by Default (Adjustable) | General Display:16 Characters x 2 Lines Alpha Numeric LCD Display Format : Temp. & Parameter Simultaneously Real Time Display : 24 Hour Mode with Date & Time Controls : By Soft Keys Menu Driven Storage/Memory : Up to 1000 Samples Power Supply : 230 V +- 10%, 50 Hz AC / 12 V Battery Rechargeable Print Format : All Data & Date Wise (Programmable) Error Indication : pH Error, ORP Error, T-Error |
Option Available RS-232 & Parallel output available for interfacing to Computer & Printer. |
Additional Information:
Product Details:
Minimum Order Quantity | 1 Number |
Material | housed in a briefcase |
Automation Grade | Semi-Automatic |
Usage/Application | Suitable for measurement of 8 parameters - pH, ORP, Cond., TDS, Salinity, DO, Turbidity & Temp. |
Weight | 6.5 Kg |
Brand | VSI |
Model Name/Number | VSI-302 |
Application | Laboratory Use, Industrial Use |
Display Type | 16x2 Alphanumeric LCD Display |
Product Type | Multi Parameter Instrument for Water/Soil Testing |
Country of Origin | Made in India |
The VSI make Portable Microprocessor Based Water/Soil Analysis Kit (VSI-302) is suitable for measurement of eight (8) parameters i.e. pH, ORP, Conductivity, Salinity, Dissolved Oxygen, Temperature, TDS and Turbidity of any solution.
Technical Specifications :
Ph Measurement
Measurement:
Conductivity Measurement
SALINITY MEASUREMENT
Temperature Measurement
General
Storage Memory : Up to 1000 Samples
Additional Information:
Product Details:
Minimum Order Quantity | 1 Number |
Application | Used to check multi-parameters of Water and Soil, Industrial/Laboratories/in Fields |
Type | Portable |
Brand | VSI |
Model Name/Number | VSI-06, VSI-07, VSI-06T, VSI-06D, VSI-06D1 |
Display | 3 1/2 Digit LCD |
Power Supply | 230V +/- 10%, 50Hz AC / 9V Battery |
VSI Electronics Pvt. Ltd., is leading manufacturer, supplier and exporter of multi-parameter Digital Water & Soil Analysis Kits and Microprocessor based Water/Soil Testing Kits. These Digital Water & Soil Testing Kits comprise of all types of advanced water and soil testing parameters. All our Digital Water & Soil Testing Kits are known for preciseness with which they check the pH, ORP, Conductivity, TDS, Salinity, Dissolved Oxygen, Turbidity and Temperature.
The VSI make Portable Digital Water & Soil Testing Kit is available in seven different models suitable for measurement of Dissolved Oxygen, Oxidation Reduction Potential (ORP), Total Dissolved Solids (TDS), Conductivity, Salinity, Temperature and Turbidity (depending on the model). These mains/battery operated Digital Water & Soil Testing Kits are housed in a rugged fiberglass briefcase with provision to keep all the accessories inside. Because of its compactness, these Digital Water & Soil Testing Kits are useful in field as well as laboratory.
These Digital Water & Soil Testing Kits with the use of all solid state components and latest LSI technology are very much reliable in the tough environments of the field. Model can be selected as per parameters required.
Additional Information:
Product Details:
Type | Portable |
Brand | VSI |
Model | VSI-06/07 |
Application | Industrial Use, Laboratory Use |
Material | Housed in a briefcase |
Battery Backup | Yes |
Display | 3 1/2 Digit LCD Display |
Ph Range | 0-14 pH |
Ph Resolution | 0.01 pH |
Power Supply | 230V +/- 10%, 50Hz AC / Battery |
Weight | 6.5 Kg. Approx. |
I Deal In | New Only |
Water/ Soil Analysis Kits VSI-06, VSI-06D, VSI-6D1, VSI-06T & VSI-07
The VSI make portable Digital Water/ Soil Analysis Kit consist of five models, is suitable for measurement of dissolved oxygen, oxidation reduction potential, total dissolved solids, conductivity, salinity, temperature and turbidity (depending on the model). These mains/battery operated kits are housed in a rugged fibre glass briefcase (v. I. P. Make) with provision to keep all the accessories inside. Because of its compactness these are useful in field as well as laboratory. The kits with the use of all solid state components and latest LSI technology are very much reliable in the tough environments of the field. Model can be selected as per parameters required.
Technical Specifications:
D. O. Measurement | Range Temp. Compensation (Manual) Resolution Accuracy | 0 to 20 ppm 10c to 50c 0.1 ppm. +-0.3 ppm +- 1 digit |
O. R. P. Measurement | Range Resolution Accuracy | 0 to +-1999 mV 1 mV +-1 mV +-1 digit |
pH Measurement | Range Temp. Compensation (Manual) Resolution Accuracy | 0 to 14 pH 0c to 100c 0.01 pH +-0. 01 pH +- 1 digit |
T. D. S. Measurement | Range Resolution Accuracy | 0 to 20000 mg/litre 10 mg/litre +-1% FSD +-1 digit |
Conductivity Measurement | Range
Resolution Accuracy | 0 micro mhos to 1000 milli mhos Selection in 5 steps : 100 micro mhos, 1 milli mhos 10 milli mhos, 100 milli mhos &1000 milli mhos 0.01 micro mhos +-0.5%FSD +-1 digit |
Salinity Measurement (available in model VSI-07 only) | Range Resolution Accuracy | 0 to 40 ppt 0.1c +-0.5% +-1 digit |
Temperature Measurement | Range Resolution Accuracy | 0c to 100c 0.1c +-0.5% +-1 digit |
Turbidity Measurement (Available in model VSI-06T only) | Range Resolution Accuracy Detector Light Source Sample System | o to 1000 ntu/ JTU 1 NTU/JTU +-0.3% FSD +-1 digit Photodiode 6.8V, 250 mA Lamp 30 mm dia, Clear Glass Test Tubes |
Additional Information: