Product Details:
Minimum Order Quantity | 1 Number |
Wavelength Range | 185-930 nm |
Optical System | Double Beam |
Brand | VSI |
Model Name/Number | VSI-2102 Atomic Absorption Spectrophotometer |
Grating | 1800 Lines grating (USA) |
Light Source | 8 Lamp Turret |
Range | 185-930 nm. |
DTECTOR | High performance multi-alkali Photo multiplier tube R928 |
MOTORIZED LAMP TURRET | Eight Lamp motorized turret with automatic lamp selection and individual lamp peaking automatically |
Parameter | Computer Controlled, High Performance, Optically Double Beam Atomic Absorption Spectrophotometer Hav |
AUTOMATIC FLAME CONTROL UNIT | Programmable gas controller with digital display of flow, full safety interlock including built in p |
OPTICS MONOCHROMATOR | Real time Double Beam with Deuterium background CZ design with 330mm focal length, 1800 lines/mm gra |
Atomic Absorption Spectrophotometer (Double Beam), Model: (VSI-2102), Ebert type monochromator with 1800 lines/mm halographic grating, 0 to 2nm SBW, 190-900nm Wavelength range. Eight hollow cathode lamp turret assembly with moduled eight independent power supplies. Built-in background corrector in the system using high intensity and high speed Deuterium lamp. Automatic calibration using up to maximum 10 standards and recalibration with a single standard. Direct concentration readout using different modes (K-Factor Liner regression and Quadratic regression). Display of the signal energy in the form of BAR signal and numeric form. ABS., %TRANS & CONC. Display facility. Absorbance range from 0 to 3.0 ABS. Titanium Burner of 100mm Air-acetylene and 50mm N2O – Acetylene Flames. Corrosion resistant nebulizer with Platinum – iridium capillary, Impact bead, Supplied with computer interface software.
SALIENT FEATURES:
· Highly Stable and Accurate
· True Double Beam Optics
· 8 Lamp Turret
· Range 185-930 nm.
· 1800 Lines grating (USA)
· Variable Bandwidth 0.1 to 2 nm.
· User Friendly Software
Additional Information:
Product Details:
Minimum Order Quantity | 1 Number |
Wavelength Range | 190-900nm |
Optical System | Single Beam |
Brand | VSI |
Model Name/Number | VSI-2100 Atomic Absorption Spectrophotometer |
Photometric Range | 190-900 nm |
Data Output Port | RS232 |
Dimensions | 100x55x58 cm. (LxHxB) |
Lamps | 4 Lamp Turret |
Detector | High performance multi-alkali Photo multiplier tube R928 |
Atomic Absorption Spectrophotometer (Single Beam), Model: (VSI-2100), Ebert type monochromator with 1800 lines/mm halographic grating, 0 to 2nm SBW, 190-900nm Wavelength range. Eight hollow cathode lamp turret assembly with moduled eight independent power supplies. Built-in background corrector in the system using high intensity and high speed Deuterium lamp. Automatic calibration using up to maximum 10 standards and recalibration with a single standard. Direct concentration readout using different modes (K-Factor Liner regression and Quadratic regression). Display of the signal energy in the form of BAR signal and numeric form. ABS., %TRANS & CONC. Display facility. Absorbance range from 0 to 3.0 ABS. Titanium Burner of 100mm Air-acetylene and 50mm N2O – Acetylene Flames. Corrosion resistant nebulizer with Platinum – iridium capillary, Impact bead, Supplied with computer interface software.
SALIENT FEATURES:
· Highly Stable and Accurate
· Single Beam Optics
· 4 Lamp Turret
· Range 190-900 nm.
· 1800 Lines grating (USA)
· Variable Bandwidth 0.1 to 2 nm.
· User Friendly Software
Additional Information: